Wednesday, August 3, 2016

2016NEW VMWare.VCP-510 EXAM] EXAM C PART3 (51-70) VCE DUMPS FOR FREE DOWNLOAD WITH 100%PASS ENSURE

Do you want to pass the VCP-510 Examsavior exam? What are the new questions of the latest VCP-510 exam? Examsavior VCP-510 VCE dumps and VCP-510 PDF dumps will tell you all about the VCP-510 Examsavior exam.Here are the Examsavior newest and covered all new added questions and answers, which will help you 100% passing  VCP-510 Examsavior exam.Hurry up and get the free exam from here!
NOW FREE DOWNLOAD
http://examsavior.com/70-414


QUESTION 51
In vSphere, a bound physical NIC can be configured to transmit and receive jumbo frames.
What is the default maximum transmission unit (MTU) in vSphere?
A. 1500
B. 5500
C. 9000
D. 9500
QUESTION 52
On which two vSphere elements can traffic shaping be configured? (Choose two.)
A. On a vSphere Distributed Switch dvPort for inbound and/or outbound traffic
B. On a vSphere Distributed Switch for inbound and/or outbound traffic
C. On a vSphere Standard Switch port group or the entire vSwitch for inbound traffic
D. On a vSphere Standard Switch port group or the entire vSwitch for inbound and outbound traffic
QUESTION 53
In a vSphere HA cluster, what is the maximum number of point-to-point communication links to the slaves
does each master maintain?
A. 32
B. 64
C. 512
D. 1024
QUESTION 54
During peak operating hours, an administrator finds that a business-critical application running in a virtual
machine is not performing as well as during normal hours.
Which memory management method can be used to guarantee that the application performs well at all
times?
A. Set a reservation equal to the average memory utilization of the virtual machine running the
application.
B. Set the share level to high for the virtual machine running the application and set the share level for all
other virtual machines to low.
C. Check the Reserve all guest memory checkbox.
D. Set a reservation equal to the installed memory of the ESXi host running the application.
QUESTION 55
A vSphere environment is created with two virtual machines, VM23 and VM43.
Each virtual machine has an instance of the front-end web application for the company’s manufacturing
management database.
A physical load-balancer is configured for the application.
Which type of DRS rule should be implemented for VM23 and VM43?
A. Separate Virtual Machines
B. Virtual Machines to Hosts
C. Host DRS Groups
D. Keep Virtual Machines Together
QUESTION 56
Which three services will continue to function when vCenter Server is unavailable? (Choose three.)
A. Storage DRS
B. Fault Tolerance (FT)
C. vMotion
D. Thin Provisioning
E. High Availability
QUESTION 57
A request has been made to the SAN administrator to provision a new LUN.
A LUN (LUN 6) is created, and the SAN administrator presents the LUN to an ESXi 5.x host, using the
storage array SAN management software.
The administrator looks at the Storage configuration for the ESXi host, and does not see the new LUN.
Other LUNs from the same storage array are visible.
Which two conditions are most likely to cause the error described? (Choose two.)
A. The administrator has not performed a Rescan All on the ESXi host.
B. The multipathing policy has been set to Fixed for the LUN.
C. Zoning on the Fibre Channel switches is not configured correctly.
D. The LUN was not presented to the correct ESXi host.
QUESTION 58
A database administrator has reported periodic poor performance on a particular virtual machine.
The virtual machine administrator has noticed a significant drop in performance when utilized memory
exceeds 1GB.
What does this indicate and what could be checked next?
A. The application problems are definitely due to a non-memory-related problem. CPU affinity settings
should be checked for this virtual machine.
B. The application problems are definitely due to a non-memory-related problem. CPU utilization should
be checked next, using Windows Task Manager.
C. The virtual machine might not have physical memory available. Compression and swap activity on the
ESXi host should be checked next.
D. The virtual machine might not have physical memory available. Ensure the memory limit on the VM is
set to 0 MB.
QUESTION 59
What would be a valid reason to enable traffic shaping?
A. Limiting the bandwidth of a FTP server
B. Restricting the load on a IDS server
C. Limiting the bandwidth used by an independent hardware iSCSI adapter
D. Improving the performance of a CPU-intensive application server
QUESTION 60
Users have reported performance issues with an application running on a Windows VM.
Performance analysis shows high CPU activity on the ESXi host but low CPU activity on the Windows VM.
A high value in which overview graph and counter on the virtual machine’s Performance tab would confirm
the results of the performance analysis?
A. CPU (%) / Wait
B. CPU Usage (Mhz) / Wait
C. CPU Usage (Mhz) / Ready
D. CPU (%) / Ready
QUESTION 61
Which option could be used for vSphere HA heartbeats?
A. An iSCSI LUN used for booting the master ESXi host.
B. An iSCSI LUN backing an RDM connected over 10GB Ethernet
C. An NFS datastore shared with the all hosts, sync, no_root_squash and read only options
D. A Fibre Channel LUN on an 8GB active/active array backing a VMFS5 datastore
QUESTION 62
The performance graph for a virtual machine with 1GB of RAM shows the Swap In rate to be 150 MBps
and the Balloon value to be at 0 MB.
Users of the virtual machine are complaining that performance is slow.
Which two actions could increase performance of the virtual machine? (Choose two.)
A. Install the VMMEMCTL driver on the ESXi host.
B. Increase the memory share value for this virtual machine.
C. Install VMware Tools into this virtual machine.
D. Disable swapping in the virtual machine operating system.
QUESTION 63
2016NEW VMWare.VCP-510 EXAM] EXAM C PART3 (51-70) VCE DUMPS FOR FREE DOWNLOAD WITH 100%PASS ENSURE
An administrator has received reports of poor network performance with a virtual machine.
Which task will improve the network performance of this virtual machine?
A. Adjust shares for the virtual NIC on the virtual machine.
B. Traffic-shape this virtual machine.
C. Move the virtual machine to another virtual switch.
D. Add a CPU to the virtual machine.
QUESTION 64
Which two components can be installed in monitored virtual machines to trigger vSphere HA Application
Monitoring? (Choose two.)
A. A custom script utilizing the appmonitor executable
B. The vSphere Fault Tolerant agent
C. Third-party utilities such as Neverfail or ApplicationHA
D. The vSphere HA application agent
QUESTION 65
What are two considerations when using resource pools in a vSphere cluster? (Choose two.)
A. Default shares are equal for all sibling resource pools, regardless of virtual machines or child pools
B. By default, Reservations can be exceeded
C. vMotion must be setup prior to creating Resource Pools
D. DRS rules cannot violate Resource Pool membership
QUESTION 66
A vSphere 5.x implementation contains two ESXi hosts, ESXi01 and ESXi02.
There is a virtual machine “VM21” connected to the Production port group on ESXi01.
ESXi01 has the following switch configuration.
vSwitch0, single uplink to 10.1.20.0/24 – Production port group – VMkernelport for vMotion –
VMKernel port for management
vSwitch1, single uplink to 10.1.40.0/24 – Engineering port group – VMKernel port for NFS storage
ESXi02 has the following switch configuration.
vSwitch0, single uplink to 10.1.20.0/24 – Engineering port group – VMkernel port for vMotion –
VMKernel port for management
vSwitch1, single uplink to 10.1.40.0/24 – Production port group – VMKernel port for NFS storage
Which two statements are true about this configuration? (Choose two.)
A. vMotion is not available between the two hosts
B. If VM21 is migrated to ESXi02 it will not be available on the network
C. The virtual machine can be vMotion migrated to the target host.
D. Broadcasts from the Production port group will not reach the Engineering port group.
QUESTION 67
When comparing software iSCSI initiators with independent hardware initiators,
what are the additional CHAP security levels available for a software implementation? (Choose two.)
A. Do not use CHAP unless required by target
B. Use CHAP
C. Use CHAP unless prohibited by target
D. Do not use CHAP
QUESTION 68
The storage administrator is preparing an action plan to upgrade a Fibre Channel storage array.
The current plan will result in extended downtime for a VMFS LUN that is part of a SDRS cluster.
What steps can be taken in a vSphere 5.x environment to minimize the impact of the downtime? (Choose
two.)
A. Ensure there are multiple active paths to the LUN
B. Ensure DRS is configured properly
C. Use Storage vMotion to migrate the affected VMDKs
D. Place the datastore into maintenance mode
QUESTION 69
Which two types of information can be obtained about a VMFS datastore using the Summary tab for a
connected host in the vSphere Client? (Choose two.)
A. Multipathing status for the datastore
B. Hardware Acceleration status
C. Alarm Actions status for the datastore
D. Runtime name of the datastore
QUESTION 70
What are three reasons for deploying vCenter Server in a physical machine? (Choose three.)
A. vCenter Server can be deployed as a physical machine to support a VSA configuration.
B. vCenter Server can be deployed as a physical machine to ensure it is not susceptible to vSphere
outages.
C. vCenter Server can be deployed as a physical machine to improve VMware Data Recovery
performance.
D. vCenter Server can be deployed as a physical machine to improve vMotion performance.
E. vCenter Server can be deployed as a physical machine to ensure it does not contend for resources.
QUESTION

Latest online browsing the VCP-510 exam!
VCP-510 PDF dumps & VCP-510 VCE dumps: http://examsavior.com
 ESTKPSATOB
 
Test King
Pass4sure
Actual Tests
Other Brands
Customer Reviews5stars1star1star1star1star
 
$89.99
$124.99
$125.99
$189.00
$29.99~$49.99
Up-To-DatedAvailableNotAvailableNotAvailableNotAvailableNotAvailable
Real Questions & AnswersAvailableNotAvailableNotAvailableNotAvailableNotAvailable
Correct All ErrorAvailableNotAvailableNotAvailableNotAvailableNotAvailable
Premium VCE DumpsAvailableNotAvailableNotAvailableNotAvailableNotAvailable
Free VCE SimulatorAvailableNotAvailableNotAvailableNotAvailableNotAvailable
Unlimited After One Time PurchasingAvailableNotAvailableNotAvailableNotAvailableNotAvailable
Instant DownloadAvailableNotAvailableNotAvailableNotAvailableNotAvailable
Printable PDF DumpsAvailableNotAvailableNotAvailableNotAvailableNotAvailable
100% Pass GuaranteeAvailableNotAvailableNotAvailableNotAvailableNotAvailable
100% Money BackAvailableNotAvailableNotAvailableNotAvailableNotAvailable

No comments:

Post a Comment